Special Design for Malaria Diagnosis - Testsea Disease Test H.pylori Ab Rapid Test Kit – TESTSEA

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Fast and great quotations, informed advisers to help you choose the correct solution that suits all your requirements, a short creation time, responsible top quality manage and distinct providers for paying and shipping affairs for Typhidot Test Kit , Hbsag Blood Test , Malaria Testing Kits For Sale , We are going to do our greatest to satisfy or exceed customers' prerequisites with excellent goods, advanced concept, and economical and timely company. We welcome all clients.
Special Design for Malaria Diagnosis - Testsea Disease Test H.pylori Ab Rapid Test Kit – TESTSEA Detail:

Brand Name:

testsea

Product name:

H.Pylori Ab Test

Place of Origin:

Zhejiang, China

Type:

Pathological Analysis Equipments

Certificate:

ISO9001/13485

Instrument classification

Class II

Accuracy:

99.6%

Specimen:

Whole Blood/Serum/Plasma

Format:

Cassete/Strip

Specification:

3.00mm/4.00mm

MOQ:

1000 Pcs

Shelf life:

2 years

HIV 382

Allow the test, specimen, buffer and/or controls to reach room temperature 15-30℃ (59-86℉) prior to testing.

1. Bring the pouch to room temperature before opening it. Remove the test device from the sealed pouch and use it as soon as possible.
2. Place the test device on a clean and level surface.
3. For serum or plasma specimen: Hold the dropper vertically and transfer 3 drops of serum or plasma (approximately 100μl) to the specimen well(S) of the test device, then start the timer. See illustration below.
4. For whole blood specimens: Hold the dropper vertically and transfer 1 drop of whole blood(approximately 35μl) to the specimen well(S) of the test device, then add 2 drops of buffer (approximately 70μl) and start the timer. See illustration below.  
5. Wait for the colored line(s) to appear. Read results at 15 minutes. Do not interpret the result after 20 minutes.  

Applying sufficient amount of specimen is essential for a valid test result. If migration (the wetting of membrane) is not observed in the test window after one minute, add one more drop of buffer (for whole blood) or specimen (for serum or plasma) to the specimen well.

Interpretation of Results

Positive: Two lines appear. One line should always appear in the control line region(C), and another one apparent colored line should appear in the test line region.

Negative: One colored line appears in the control region(C).No apparent colored line appear in the test line region.

Invalid: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure.

★ Review the procedure and repeat the test with a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

Honorary certificate

Exhibition Information (6)


Product detail pictures:

Special Design for Malaria Diagnosis - Testsea Disease Test H.pylori Ab Rapid Test Kit – TESTSEA detail pictures

Special Design for Malaria Diagnosis - Testsea Disease Test H.pylori Ab Rapid Test Kit – TESTSEA detail pictures


Related Product Guide:

Our company has been concentrating on brand strategy. Customers' pleasure is our greatest advertising. We also source OEM service for Special Design for Malaria Diagnosis - Testsea Disease Test H.pylori Ab Rapid Test Kit – TESTSEA, The product will supply to all over the world, such as: Liverpool, Slovakia, Slovenia, With the goal of "zero defect". To care for the environment, and social returns, care employee social responsibility as own duty. We welcome friends from all over the world to visit and guide us so that we can achieve the win-win goal together.
  • In China, we have purchased many times, this time is the most successful and most satisfactory, a sincere and realiable Chinese manufacturer!
    5 Stars By Doris from Seychelles - 2018.04.25 16:46
    Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!
    5 Stars By Danny from Eindhoven - 2017.12.09 14:01

    Send your message to us:

    Send your message to us:

    Write your message here and send it to us